AQUAMATER

Products · Antibacterial filters

Bacteria-free water
at the last centimetre
before the user.

The hollow fibre membrane does not reduce the bacterial load: it excludes it, mechanically, at the point where the water meets the person. It is the only measure that takes effect from the very first second, whatever is happening upstream in the network.

Technology

How a hollow
fibre membrane
works.

The heart of the filter is a bundle of hundreds of hollow polymer capillaries, fractions of a millimetre in diameter, sealed at their ends in a resin that forces all the water through their wall. It is that wall, not a bed of material, that does the filtering.

The capillary wall has an absolute pore size of 0.2 µm: retention is steric, that is, purely dimensional. Whatever is larger than the pore does not pass, ever, regardless of the incoming load, the contact time or saturation — unlike systems that work by adsorption or chemical action and lose effectiveness as they are used up.

The hollow fibre format serves a second purpose: fitting many square metres of filtering surface into a few cubic centimetres. It is this density that allows a comfortable flow rate to be maintained — from 10 to over 20 litres per minute depending on the model — despite sterile-grade filtration.

Hollow fibre filter cartridges: the bundle of capillaries is sealed at its ends to force the water through the membrane wall.
Origin

Designed and manufactured
in Germany.

The filters we supply come from Aqua free, a Hamburg company specialising exclusively in water hygiene, which develops and manufactures in its own plants in Germany and Belgium — membranes included. This is not the assembly of bought-in components: the chain, from fibre to finished product, stays in-house.

In-house production

Manufacturing plants in Germany and Belgium: the membranes and filter cartridges are developed and made in-house, not bought from third parties.

ISO 9001 · 14001 · 13485

Management system certified for quality, environment and — with ISO 13485 — for the manufacture of medical devices.

CE medical devices

The filters in the Baclyser® range are CE-marked medical devices, developed in collaboration with European university hospitals.

Individual traceability

Every filter carries a unique marking: installation date, expiry and batch go into the maintenance log.

The catalogue

Choose by
application.

Filter the range by context of use: anti-Legionella protection at points of use, or sterile filtration for medical equipment and procedures.

Point-of-use

Anti-Legionella filters
for points of use.

Showers, taps and filling points: the barrier fits onto the outlet and protects whoever uses it, without shutting down the system and without building work.

Hand shower · hospitality venues

cBlue SC

Chrome-plated filtering hand shower

Hand shower with an integrated hollow fibre cartridge, designed for hotels, spas, wellness areas and private bathrooms: the look of standard tapware and no plumbing modifications, it screws onto the existing hose. The cartridge is replaceable at the end of its service life.

  • Membranehollow fibre
  • Retention99.99999% · 7 log
  • Service life3 or 5 months
  • Flow rate11 l/min at 3 bar · 15 l/min at 5 bar
  • ConnectionG ½″
  • DimensionsL 263 mm · Ø head 92 mm
  • Max pressure5 bar
  • Max temperature60 °C (70 °C for ≤30 min)
  • Chlorine≤10 ppm continuous · 400,000 ppm shock 1 h
Wall shower · pools and gyms

AS-Wallshower

Wall-mounted filtering shower

Fixed wall-mounted filtering shower for swimming pools, gyms, changing rooms and sports centres: it delivers pathogen-free water while keeping a satisfactory flow rate even in systems with low operating pressures. Robust, vandal-resistant body, suited to intensive collective use.

  • Membranehollow fibre
  • Retention99.9999% · log 7
  • Service lifeup to 120 days
  • Installationfixed to wall
  • Notesstable flow rate even at low pressure
Tap · flat membrane

Baclyser® neo T

Terminal filter for taps

Terminal filter with a flat membrane and increased clearance under the tap: maximum flow rate and minimum bulk over the basin. MetalSkin® 2 antibacterial coating on the external surfaces, quick-fit connector for replacement in a few seconds.

  • Membraneflat · 0.2 µm
  • Retention≥7 log (ASTM F838-20)
  • Service life31 / 62 / 93 days
  • Flow rate15.5 l/min at 5 bar · 13.1 l/min at 3 bar
  • Connectionquick-fit
  • Dimensions49.3 mm × Ø 52 mm
  • Max pressure5 bar
  • Max temperature60 °C
  • CoatingMetalSkin® 2 (ISO 22196)
Tap · hollow fibre

Baclyser® TL / TR

Single-use terminal filter for taps

Hollow fibre terminal filter for ward basins, operating theatres, clinics, laboratories and ward kitchens. TL version with lateral jet and TR with vertical jet, both with a quick-fit connector and bacteriostatic housing.

  • Membranehollow fibre · 0.2 µm
  • Retention≥7 log (ASTM F838-15a)
  • Service life31 / 62 / 93 days
  • Flow rate10 l/min at 5 bar and 30 °C
  • Connectionquick-fit
  • DimensionsL 105 × Ø 44 mm · H 51 (TL) / 60 (TR)
  • Max pressure5 bar
  • Max temperature60 °C (70 °C for ≤30 min)
  • Chlorine≤10 ppm · 400,000 ppm shock 1 h
Shower · high flow rate

Baclyser® neo S

Single-use sterile shower

Single-use sterile shower head with the longest service life in the range: up to four months in operation. Comfortable jet thanks to the large filtering surface, MetalSkin® coating against retrograde recontamination.

  • Membranehollow fibre · 0.2 µm
  • Retention≥7 log (ASTM F838-20)
  • Service life62 / 93 / 124 days
  • Flow rate15 l/min at 5 bar · 11 l/min at 3 bar
  • ConnectionG ½″
  • DimensionsL 256 mm · Ø head 92 mm
  • Max pressure5 bar
  • Max temperature60 °C (70 °C for ≤30 min)
  • Chlorine≤10 ppm · ClO₂ ≤0.8 mg/l
Shower · standard

Baclyser® S

Single-use sterile shower

The standard solution for ward showers, care homes and changing rooms: compact body, G ½″ connection on the existing hose, bacteriostatic material in the housing and bactericidal at the outlet.

  • Membranehollow fibre · 0.2 µm
  • Retention≥7 log (ASTM F838-15a)
  • Service life31 / 62 / 93 days
  • Flow rate10 l/min at 5 bar and 30 °C
  • ConnectionG ½″
  • DimensionsL 220 × Ø 44 mm
  • Max pressure5 bar
  • Max temperature60 °C (70 °C for ≤30 min)
  • CoatingMetalSkin®
Accessory

Tap adaptors

For Baclyser® neo T and TL / TR

Set of adaptors that brings the filter’s quick-fit connector onto the threads of existing tapware, without replacing the mixer. They stay fitted to the tap: periodic filter replacement is done in a single movement, without tools.

  • CompatibilityBaclyser® neo T · Baclyser® TL / TR
  • Systemquick-release fit
  • Installationon the existing tap thread
  • Threadsavailable in the most common sizes
Filling · tanks

AS Fill

Filter for filling points

Sterile filter for filling tanks and cisterns: bacteria-free water even when the draw-off point is not under control. Supplied complete with fittings and filling hose in a hard case.

  • Membranehollow fibre
  • Retention99.99999% · 7 log
  • Service lifeabout 6 months · up to 13 m³
  • Flow rate22 l/min at 5 bar and 20 °C
  • ConnectionG ½″ with fittings supplied
  • DimensionsL 150 × Ø 61 mm
  • Pressure3 – 5 bar
  • Chlorine≤10 ppm
Medical applications

Sterile filtration
for equipment
and procedures.

When water comes into contact with wounds, mucous membranes or immunocompromised patients, the filter is not an environmental precaution: it is part of the medical device.

Product photo — Baclyser® WG

Birthing pools and burns units

Baclyser® WG

Sterile in-line filter

In-line filter for the inlets of birthing pools and baths for severe burns patients, where the patient stays immersed for a long time and the barrier has to sustain high flow rates. Bacteriostatic housing against retrograde contamination, CE-marked medical device.

  • Membranehollow fibre · 0.2 µm
  • Retention≥7 log (ASTM F838-15a)
  • Service lifeup to 3 months
  • Flow rate22 l/min at 5 bar and 20 °C
  • Connectionquick-fit
  • DimensionsL 150 × Ø 61 mm
  • Max pressure5 bar
  • Max temperature40 °C
  • ClassificationCE medical device

Product photo — Baclyser® IL

High flow rates · group protection

Baclyser® IL 3 · 5 · 10

Sterile in-line filter

High-flow in-line filter installed upstream of a group of outlets: it protects several terminals with a single device. Three versions for increasing filtered volumes, chosen according to the actual consumption of the branch served.

  • VersionsIL 3 · IL 5 · IL 10
  • Filtered volumeup to 3,000 / 13,000 / 56,000 litres
  • Connections8 mm quick-fit or G ½″
  • Installationin-line, upstream of the group of outlets
  • ClassificationCE medical device

Product photo — Baclyser® IL DENT

Dentistry

Baclyser® IL DENT

In-line filter for dental units

In-line filter on the cold water supply of the dental unit: it protects turbines, air-water syringes and the cup filler, where stagnation in the narrow lines and biofilm are the norm. Up to six months in operation.

  • Applicationdental units
  • Installationin-line on the cold water
  • Service lifeup to 6 months
  • ClassificationCE medical device

Product photo — Baclyser® ENT

Otolaryngology

Baclyser® ENT

Sterile in-line filter for ENT units

Sterile in-line filter for ENT units, in particular for caloric testing of the ear, where the water comes into direct contact with the ear canal. Luer-Lock connection, minimal bulk.

  • Membranehollow fibre · 0.2 µm
  • Retention≥7 log (ASTM F838-15a)
  • Service lifeup to 4 weeks
  • Flow rate≥0.5 l/min at 5 bar and 25 °C
  • ConnectionLuer-Lock
  • DimensionsL 56 × Ø 18 mm
  • Max pressure5 bar at 50 °C
  • Chlorine≤10 ppm
How they fit into the plan

A barrier, not an alibi.

The filter protects the person, it does not remediate the network. In the prevention plan it has three precise roles, and in none of the three does it replace remediation.

Replacement and log
The stated service life is a maximum: it depends on water quality, pressure and frequency of use. Every filter must be logged with its installation date and expiry; in BRIQ SAFE the replacement becomes an assigned task with automatic notification.
Presentation — Antibacterial filters

Space reserved for the service presentation. Open this section with Elementor and paste the embed code here (SlideShare, Google Slides, Issuu or a flipbook PDF).

Let’s talk

Tell us about your system.
We design safe water and air.