AQUAMATER

Services · Sampling and analysis

Data is worth
only as much as
whoever collects it.

Sampling that is badly designed or badly executed produces figures that say nothing — or worse, reassure you wrongly. Our technicians are trained and qualified on sample collection protocols, and every sample is analysed by ACCREDIA-accredited laboratories.

Trained and qualified technicians

Sample collection is a
technical act, not an
errand.

The difference between a representative sample and a useless one lies in details that cannot be improvised: sampling point, run-off time, temperature at the moment of collection, whether or not the outlet is disinfected, container, neutraliser, transport temperature and transport times.

ACCREDIA laboratories

Accredited methods,
test reports that
stand up.

We work exclusively with laboratories accredited by ACCREDIA under UNI CEI EN ISO/IEC 17025. This is not a bureaucratic detail: the test report of an accredited laboratory stands up before the health authority, in an accreditation audit and in court.

For Legionella the reference is UNI EN ISO 11731; for drinking water compliance parameters, the methods set out by Legislative Decree 18/2023 and the ISTISAN reports. The result never arrives as an isolated number: we read it in the context of the system and translate it into operational consequences.

We do not hand over a number
Every test report comes with a technical note explaining what the result means for that particular system, whether it calls for immediate action, and which action.
Water analysis

What we look for
in the water.

The analytical panel is built around the objective: Legionella surveillance, drinking water compliance checks, post-remediation control or the investigation of a clinical case each call for different parameters.

Legionella spp. and L. pneumophila

Detection and enumeration to UNI EN ISO 11731, with serogrouping on request. The cornerstone parameter of every control plan.

Pseudomonas aeruginosa

An indicator of biofilm and of critical conditions at terminal outlets, decisive in areas with vulnerable patients and in domestic water circuits.

Intestinal Enterococci

An indicator of faecal contamination, a mandatory microbiological parameter for drinking water compliance.

Escherichia coli and coliforms

Indicators of contamination and of the integrity of the internal distribution network.

Total bacterial count at 22 and 36 °C

A general indicator of the hygienic state of the network and of the effectiveness of treatments.

Chemical parameters and lead

Metals, hardness, chlorites and chlorates, disinfection by-products, lead from the materials of the internal network.

Air and surface analysis

What the water
does not tell you.

The microbiological contamination of a building does not travel through water alone. Air and surfaces tell you the state of the air handling systems, of the cleaning procedures and of the areas at risk.

Air: total bacterial count

Active sampling onto culture medium with an orthogonal impact sampler, per unit of volume: the reference measure of the hygienic state of the environment.

Air: moulds, yeasts and fungal spores

Detection and enumeration of airborne fungal colonies with identification of the genera: Aspergillus, Cladosporium, Penicillium, Alternaria, Fusarium.

Air: particulate matter and dust

Determination of airborne dust and verification of the efficiency of the filtration systems.

Surfaces: microbial counts

Swabs and contact plates on critical surfaces, with enumeration of the total bacterial count and the fungal count.

Surfaces: indicator pathogens

Targeted detection of staphylococci, enterobacteria and other indicators in healthcare areas, professional kitchens and controlled-contamination environments.

Ducts and terminal units

Sampling of the internal surfaces of ducts, coils and condensate trays in support of the hygiene assessment of the system.

Drinking water compliance · Legislative Decree 18/2023

Internal checks
under the decree
of February 2023.

Legislative Decree 18 of 23 February 2023 transposes Directive (EU) 2020/2184 and carries responsibility for water quality right inside the building: the water utility answers up to the point of delivery, and from the meter onwards the owner or the manager of the facility answers.

Let’s talk

Tell us about your system.
We design safe water and air.

Technical consultancy, risk assessment, bespoke design and tailored quotations for healthcare facilities, hotels, industry, public bodies, resellers and distributors all over the world.