AQUAMATER

Air hygiene services

Services · Air handling systems

Inspect,
document,
then remediate.

No air handling system is cleaned «by feel». The correct route is always the same: technical inspection to recognised protocols, objective sampling, a system hygiene management plan, and only then robotic remediation and sanitisation, with final verification.

01

Technical inspections
to the best recognised international protocols and standards

The inspection is the document that justifies — or rules out — the intervention. We carry it out to the leading reference protocols worldwide, consistent with the Italian State-Regions Agreement of 5 October 2006.

02

System hygiene
management plan

The inspection captures the current state; the hygiene management plan sets out how to maintain it. It is the document that turns a one-off remediation into a verifiable hygiene maintenance programme, one that can be built into the facility contract and the risk assessment document (DVR).

System register

Survey of AHUs, supply and return networks, outlets, access hatches and critical points, with updated layout drawings.

Frequencies and responsibilities

Definition of the inspection and sanitisation activities, the minimum frequencies and the person responsible for each one.

Acceptability criteria

Objective deposit and microbial load thresholds above which remediation is triggered, with a declared verification method.

Records and checks

Activity log, sampling results, non-conformities and corrective actions, periodic review of the plan.

03 · Remediation

Robotic cleaning
and extraction systems.

Air hygiene remediation is not a matter of spraying product into the ducts. It is mechanical removal of the deposit, capture under negative pressure and only then sanitisation of the cleaned surfaces.

01

Sectioning and protection

The system is sectioned run by run, the terminals protected and the rooms isolated to prevent dust escaping during the work.

02

Robotic mechanical cleaning

Robots with rotating brushes and friction heads detach the deposit from the internal duct walls, including runs the operator cannot reach.

03

Negative-pressure extraction

The system is held under negative pressure by extraction units fitted with absolute HEPA filtration: the removed material is captured and not returned to circulation.

04

Sanitisation

Application of registered sanitising products by controlled fogging onto clean surfaces: sanitisation follows cleaning, it does not replace it.

05

Final verification

Post-works CCTV inspection, verification sampling and a closing report with before/after photographic documentation for every run.

Applications

Where we work.

Healthcare facilities and care homes

Operating theatres, wards and controlled-contamination areas: management of absolute HEPA filters, leak testing and verification of ventilation parameters.

Hospitality and offices

Distribution networks, fan coil and cassette terminal units, humidifier sections and heat recovery units.

Professional kitchens

Extraction hoods, plenums, fume exhaust ducts and flues: hygiene and fire risk prevention.

Industry and process

Local exhaust ventilation systems, extraction networks, booths and process ducts.

Let’s talk

Tell us about your system.
We design safe water and air.

Technical consultancy, risk assessment, bespoke design and tailored quotations for healthcare facilities, hotels, industry, public bodies, resellers and distributors all over the world.